Management and Configuration Guide K/KA/KB.15.15

Example
To use Xmodem to copy the output of show config to a serially connected PC:
Figure 128 Sending command output to a file on an attached PC
NOTE: The command you specify must be enclosed in double quotation marks.
Copying Event Log output to a destination device
Syntax
copy event-log smm [ tftp | usb | xmodem ]
Syntax
copy event-log tftp ip-address filepath_filename [oobm]
Syntax
copy event-log usb filename
Syntax
copy event-log xmodem filename
These commands copy the Event Log content to a remote host, attached USB device,
or to a serially connected PC or UNIX workstation.
When used with the smm option, the entire Event Log, both active management
module events and standby management module events, is copied to the selected
host, USB device, or serially connected PC or UNIX workstation.
For switches that have a separate OOBM port, the oobm parameter specifies that
the transfer is through the OOBM interface. If this parameter is not specified, the
transfer is through the data interface. The oobm parameter is not available on
switches that do not have a separate OOBM port.
Example
To copy the event log to a PC connected to the switch:
Figure 129 Sending event log content to a file on an attached PC
Copying crash data content to a destination device
This command uses TFTP, USB, or Xmodem to copy the Crash Data content to a destination device.
You can copy individual slot information or the management module’s switch information. If you
do not specify either, the command defaults to the management function’s data.
Syntax
copy crash-data [ slot-id | master ]
Copying diagnostic data to a remote host, USB device, PC, or UNIX workstation 285