Management and Configuration Guide K/KA/KB.15.15

Example 123 Transceiver information displayed with the detail parameter
When the show interfaces transceiver <port-list>detail command is executed,
the following information displays.
Table 27 General transceiver information
DescriptionParameter
The switch interface numberInterface Index
Pluggable transceiver typeTransceiver-type
Pluggable transceiver modelTransceiver model
Type of connector of the transceiverConnector-type
For an optical transceiver: the central wavelength of the laser sent, in nm. If the transceiver
supports multiple wavelengths, the values will be separated by a comma.
Wavelength
Link-length supported by the transceiver in meters. The corresponding transfer medium
is shown in brackets following the transfer distance value, for example, 50um multimode
fiber. If the transceiver supports multiple transfer media, the values are separated by a
comma.
Transfer Distance
Shows whether the transceiver supports diagnostics:Diagnostic Support
None Supported
DOM Supported
VCT Supported
Serial number of the transceiverSerial Number
The information in Table 28 (page 452), Table 29 (page 452), and Table 30 (page 453) is only
displayed when the transceiver supports DOM.
Table 28 DOM information
DescriptionParameter
Transceiver temperature (in degrees Centigrade)Temperature
Supply voltage in transceiver (Volts)Voltage
Laser bias current (mA)Bias
Rx power (mW and dBm))RX power
Tx power (mW and dBm)TX power
The alarm information for GBIC/SFP transceivers is shown in Table 29 (page 452).
Table 29 Alarm and error information (GBIC/SFP transceivers only)
DescriptionAlarm
Incoming (RX) signal is lostRX loss of signal
Incoming (RX) power level is highRX power high
Incoming (RX) power level is lowRX power low
Transmit (TX) faultTX fault
TX bias current is highTX bias high
TX bias current is lowTX bias low
TX power is highTX power high
452 Troubleshooting