Management and Configuration Guide K/KA/KB.15.15

When the nonstop-switching option is not selected, the switch enters warm-standby redundancy
mode.
You are prompted with "All configuration files and software images on the off-line management
module will be overwritten with the data from the current active management module. Do you want
to continue [y/n]?"
The no version of the command disables redundant management. You are prompted with this
message: "The other management module may reboot and it will no longer be used for system
redundancy, except in the case of a hardware failure of the active management module. Do you
want to continue [y/n]?".
Example
The redundancy management-module command in Figure 247 (page 463) shows warm-standby
redundant management being enabled. The show redundancy command displays "Mgmt
Redundancy" as
warm-standby redundancy enabled
. Management Module 1 (MM1) is the active
management module and Management Module 2 (MM2) is the standby management module.
Figure 247 Enabling warm-standby redundancy
The redundancy management-module command in Figure Figure 248 (page 464) shows
Non-stop switching redundant management being enabled. The show redundancy command
displays "Mgmt Redundancy" as
Nonstop switching enabled
. Management Module 1 (MM1) is
the standby management module and Management Module 2 (MM2) is the active management
module.
Enabling or disabling redundant management 463