Management and Configuration Guide K/KA/KB.15.15

SSM HP J9095A System Support Module SG911BZ00N
FM1 HP J9093A Fabric Module 8200zl SG911BQ015 Enabled - 1
FM2 HP J9093A Fabric Module 8200zl SG911BQ04T Enabled - 1
A HP J9536A 20p GT PoE+/2p SFP+ v2 zl... SG0607T124 Up YES 2
B HP Enh Svs v2 zl Module Up YES 2
C HP J8702A 24p Gig-T zl Module Up NO 1
D HP J9840A Adv Svs v2 zl Module ID3ZG6N008 Up YES 2
E HP J8705A Gig-T/SFP zl Module Up NO 1
F HP J9857A Adv Svs v2 zl Module SG2ZFNX166 Up YES 2
G HP J8708A 4p 10G CX4 zl Module Up NO 1
H HP J9154A Services zl Module SG811GG01N Up NO 1
I HP J9051A Wireless Edge Services zl... SG660ZB095 Up NO 1
J HP J9545A ONE Adv Svs zl Module SG9604P933 Up NO 1
K HP J9051A Wireless Edge Services zl... 1111 Up NO 1
L HP J9154A Services zl Module SG811GG01M Up NO 1
Viewing information about the management and fabric modules
The show redundancy command displays information about the management and fabric modules.
It displays the flash image last booted from, even if the boot set-default command has been
set to change the flash booted from on the next boot.
Example
Figure 255 show redundancy command
Viewing information about the redundancy role of each management module
The show redundancy command with the detail option displays information about the
redundancy role of each management module, as well as statistical information such as how long
the module has been up.
472 Chassis Redundancy (8200zl Switches)