Figure 270 Booting the standby management module to secondary flash
CAUTION: If you have booted one module out of primary flash and one module out of secondary
flash, and the secondary flash is running a prior software version because the latest version was
never copied over from the primary flash, you will have a software version mismatch. The
configuration file may not work with that software version.
The standby module enters warm-standby redundancy mode and boots to a certain point, syncs
basic files such as the config and security files, and finishes booting only if the active management
module fails or you choose to change which module is the active module..
Additionally, if a switchover occurs, or if you reboot to make the standby module become the
active module, any configuration file changes made may not work on the active module if it has
a different software version from the standby module.
When you enter the show redundancy command and a software version mismatch exists, a
warning message is displayed, as shown at the bottom of Figure 271 (page 491).
490 Chassis Redundancy (8200zl Switches)