Management and Configuration Guide K/KA/KB.15.15

<slot-id> reload Reset the services module.
<slot-id> serial Connect to services module via
serial port.
<slot-id> shutdown Shutdown (halt) the services
module.
Boot Reboot the services module.
Integer Index of the services CLI to access.
Locator Control services module locator LED.
Name Name of the services CLI to access.
Reload Reset the services module.
Serial Connect to application via serial port.
Shutdown Shutdown (halt) the services module.
Enable or disable devices.
Enable or disable devices. This command must be run from the configure context.
Syntax
[no]services <slot> device [PXE|shutdown|USB|CF]
PXE Enable or disable booting from PXE (if supported).
shutdown Enable or disable the shutdown or reset button.
USB Enable or Disable the USB after boot.
CF Enable or disable the Compact Flash or SD1 card.
Accessing CLI-passthrough
Accessing the CLI-passthrough feature on modules that support the feature. Feature can be reported
by the show servicescommand given with no additional parameters.
Syntax
services <slot>[<index>|<name>
ASCII-STR Enter an ASCII string.
Example 48 Show services
HP-8212zl# show services
Installed Services
Slot Index Description Name
H,L 1. Services zl Module
services-module
L 2. HP ProCurve MSM765 zl Int-Ctlr
msm765-applicati
H 3. Threat Management Services zl Module tms-module
Show services set locator module
This command sets the Module Locator LED to either solid-on, off or slow-blink for a specified
duration of time or to turn it off before the previously-specified time has passed. Options are
permitted in this command for the Operator.
Viewing port status and configuration 81