Management and Configuration Guide K/KA/KB.15.15

Viewing transceiver status
The show interfaces transceivers command allows you to:
Remotely identify transceiver type and revision number without having to physically remove
an installed transceiver from its slot.
Display real-timestatus information about all installed transceivers, including non-operational
transceivers.
Figure 27 (page 86) shows sample output from the show tech transceivers command.
NOTE: Part # column in Figure 27 (page 86) enables you to determine the manufacturer for a
specified transceiver and revision number.
Figure 27 Example of show tech transceivers command
Transceiver Operating notes
The following information is displayed for each installed transceiver:
Port number on which transceiver is installed.
Type of transceiver.
Product number — Includes revision letter, such as A, B, or C. If no revision letter follows
a product number, this means that no revision is available for the transceiver.
Part number — Allows you to determine the manufacturer for a specified transceiver and
revision number.
For a non-HP switches installed transceiver (see line 23 Figure 27 (page 86)), no transceiver
type, product number, or part information is displayed. In the Serial Number field,
non-operational is displayed instead of a serial number.
The following error messages may be displayed for a non-operational transceiver:
Unsupported Transceiver. (SelfTest Err#060)
Check: www.hp.com/rnd/device_help/2_inform for more info.
This switch only supports revision B and above transceivers.
Check: www.hp.com/rnd/device_help/2_inform for more info.
Self test failure.
86 Port Status and Configuration