HP 5400R zl2 Quick Setup Guide and Safety/Regulatory Information

Maximum Operating Altitude: 3.1 km (10,000 ft)
NOTE: If you are using the J9830A power supply unit with
your switch, the maximum operating temperature is
reduced to 40°C between altitudes of 5000 feet (1.52 km)
and 10000 feet (3.1 km).
Non-Operating Altitude: 15.24 km (50,000 ft)
Safety Standards:
Lasers:
EN60950-1:2006+A11:2009+A1:2010+A12:2011 / IEC60950-1:2005; Am1:2009; CSA22.2 No.
60950-1-07 2nd; UL60950-1 2nd
EN60825-1:2007 / IEC 60825-1:2007 Class 1
Class 1 Laser Products/Laser Klasse 1
(Use only HP supported SFPs)
Electrical J9828A J9829A J9830A
Main Aux
AC voltage: 100 -127 volts; 200 - 240 volts 110 -127 volts; 200 - 240 volts 115-127; 200-
24
0 volts
115-127; 200-
240 volts
Maximum current: 8.5; 4.3 A max 12; 6.8 A max 15.5; 10 A max 15.5; 10 A max
Frequency range: 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
PoE output wattage
(MA
X)*:
275 W 900 W 1100 W 1400 W
7
HP 5400R zl2 Power Supplies
*Actual power available depends on system configuration.
Power cord, use one of the following appropriately for the power supplies:
Country/Region J9830A
Power Supply Cable
Australia/New Zealand
China
Mainland Europe/South Korea
India
Japan/Thailand
Denmark/Switzerland
United Kingdom/Hong Kong/Singapore/
Malaysia
United States/Canada 125V
South Africa
Taiwan/USA 250V
Israel
Argentina
Brazil
Chile
8121-1550
8121-1551
8121-1554
8121-1074
8121-1555
1
8121-1287
8121-1549
8121-1553
8121-1552
8120-6362
2
8121-1010
8121-0925
8121-1101
8121-0923
1
Japan: NEMA 6-20P, 200V.
2