Installation Guide ProCurve Series 8100fl Switches: Redundant Power Supply www.procurve.
ProCurve Switch 8100fl Series: Redundant Power Supply Installation Guide
© Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Hewlett-Packard.
Contents ProCurve Switch fl Redundant Power Supply. . . . . . . . . . . . . . . . . . . . . . . . . 1 Power Supply Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Power Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installing a Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EMC Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 U.S.A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Australia/New Zealand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Japan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ProCurve Switch fl Redundant Power Supply ProCurve Switch fl Redundant Power Supply For the ProCurve Switch 8100fl Series The ProCurve Switch fl Redundant Power Supply (J8732A) is an AC power supply that you can add to a ProCurve Switch 8108fl or Switch 8116fl to provide additional redundancy and to ensure switch reliability. The power supply operates between 100–240 VAC. Each component on the switch (management module, interface module, and so on) regulates its own power needs.
ProCurve Switch fl Redundant Power Supply Power Supply Features You can use a ProCurve Switch fl Redundant Power Supply in either a Switch 8108fl or Switch 8116fl. The power supply has the following features: ■ Power redundancy—if one of the power supplies in a switch fails, the redundant power supply provides enough power to continue running a fully loaded switch. ■ Power load sharing—when more than one power supply is installed, each power supply shares the power load.
ProCurve Switch fl Redundant Power Supply Power Status LEDs The LEDs that display the operational status of power supplies in a switch are located on the front panel of each power supply as shown in the illustration below. DC OK LED Fault LED AC OK LED Table 1-1 describes the meaning of the LED displays. Table 1-1. Note Power Status LEDs on Power Supply LED State Meaning AC OK Green Power supply is operating normally and AC input is in the supported range.
ProCurve Switch fl Redundant Power Supply Installing a Power Supply Installing a Power Supply This section explains how to install a power supply in a Switch 8100fl chassis. Note If you are also installing Switch fl modules, it is recommended that you complete installation of the modules before turning on the power to verify the installation.
ProCurve Switch fl Redundant Power Supply Installing a Power Supply ■ Make sure the air flow around the sides and back of the switch is not restricted. Do not cover the power supply inlet or exhaust vent. ■ Make sure that for any switch power supply slot into which a power supply is not installed, the blank cover plate is installed to cover the slot. A blank cover is required for safe operation, and to ensure proper switch cooling.
ProCurve Switch fl Redundant Power Supply Installing a Power Supply 4. Caution Push the handle up and flush with the power supply chassis. The handle should snap into place, locking the power supply into position. If the handle does not snap into a vertical position, do not force it. You may need to re-insert the power supply, taking care to adjust the handle position during the final few centimeters to successfully engage the retaining latch. 5.
ProCurve Switch fl Redundant Power Supply Removing a Power Supply Removing a Power Supply If your ProCurve Switch 8100fl is configured with redundant power supplies, you will not suffer any loss of traffic or performance if a power supply fails. Simply replace the failed component as soon as possible. The Power Status LED on the chassis and on the power supply unit itself will indicate which power supply has failed. Note The 16-slot Switch 8116fl requires two active power supplies at all time.
ProCurve Switch fl Redundant Power Supply Troubleshooting Troubleshooting After you install a power supply, check the power LEDs on the front panel to verify normal operation (as described in “Verifying a Power Supply Installation” on page 6). If the LEDs do not indicate normal operation, follow the steps in this section to diagnose the problem. Problem Solution Power supply is not connected to an active AC power source.
ProCurve Switch fl Redundant Power Supply Specifications Specifications Physical Width: 14.61 cm (5.75 in) Depth: 27.38 cm (10.78 in) Height: 8.59 cm (3.38 in) Weight: 3.18 kg (7.0 lbs) Electrical The AC Power Supply automatically adjusts to any voltage between 100–125 and 200–240 volts and either 50 or 60 Hz. AC voltage: 100–125 volts 200–240 volts Maximum current: 15.0 A max 7.
ProCurve Switch fl Redundant Power Supply Safety Information Safety Information ! Documentation reference symbol. If the product is marked with this symbol, refer to the product documentation to get more information about the product. WARNING A WARNING in the manual denotes a hazard that can cause injury or death. CAUTION A CAUTION in the manual denotes a hazard that can damage equipment.
ProCurve Switch fl Redundant Power Supply Informations concernant la sécurité Informations concernant la sécurité ! Symbole de référence à la documentation. Si le produit est marqué de ce symbole, reportez-vous à la documentation du produit afin d'obtenir des informations plus détaillées. WARNING Dans la documentation, un WARNING indique un danger susceptible d'entraîner des dommages corporels ou la mort.
ProCurve Switch fl Redundant Power Supply Hinweise zur Sicherheit Hinweise zur Sicherheit ! Symbol für Dokumentationsverweis. Wenn das Produkt mit diesem Symbol markiert ist, schlagen Sie bitte in der Produktdokumentation nach, um mehr Informationen über das Produkt zu erhalten. WARNING Symbol für Dokumentationsverweis. Wenn das Produkt mit diesem Symbol markiert ist, schlagen Sie bitte in der Produktdokumentation nach, um mehr Informationen über das Produkt zu erhalten.
ProCurve Switch fl Redundant Power Supply Considerazioni sulla sicurezza Considerazioni sulla sicurezza ! Simbolo di riferimento alla documentazione. Se il prodotto è contrassegnato da questo simbolo, fare riferimento alla documentazione sul prodotto per ulteriori informazioni su di esso. WARNING La dicitura WARNINGdenota un pericolo che può causare lesioni o morte. CAUTION La dicituraCAUTION denota un pericolo che può danneggiare le attrezzature.
ProCurve Switch fl Redundant Power Supply Consideraciones sobre seguridad Consideraciones sobre seguridad ! Símbolo de referencia a la documentación. Si el producto va marcado con este símbolo, consultar la documentación del producto a fin de obtener mayor información sobre el producto. WARNING Una WARNING en la documentación señala un riesgo que podría resultar en lesiones o la muerte. CAUTION Una CAUTION en la documentación señala un riesgo que podría resultar en averías al equipo.
ProCurve Switch fl Redundant Power Supply Safety Information (Japan) Safety Information (Japan) Japan Power Cord Warning Please use power cord supplied with your product. The power cord is not to be used with any other products.
ProCurve Switch fl Redundant Power Supply Safety Information (China) Safety Information (China) 16
ProCurve Switch fl Redundant Power Supply EMC Regulatory Statements EMC Regulatory Statements U.S.A. FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against interference when the equipment is operated in a commercial environment.
ProCurve Switch fl Redundant Power Supply EMC Regulatory Statements Japan VCCI Class A Korea Taiwan 18
ProCurve Switch fl Redundant Power Supply EMC Regulatory Statements European Community Declaration of Conformity These products are designed for operation with the ProCurve Switch 8100fl Series. Please see the Declarations of Conformity included in the ProCurve Switch 8100fl Series: Installation and Getting Started Guide.
ProCurve Switch fl Redundant Power Supply EMC Regulatory Statements — This page is intentionally unused.
ProCurve Switch fl Redundant Power Supply EMC Regulatory Statements — This page is intentionally unused.
Technical information in this document is subject to change without notice. © Copyright Hewlett-Packard Company, 2005. All rights reserved. Reproduction, adaptation, or translation without prior written permission is prohibited except as allowed under the copyright laws.