Installation Guide (J8732A) 2005-09

ProCurve Switch fl Redundant Power Supply
Specifications
Specifications
Physical
Width: 14.61 cm (5.75 in)
Depth: 27.38 cm (10.78 in)
Height: 8.59 cm (3.38 in)
Weight: 3.18 kg (7.0 lbs)
Electrical
The AC Power Supply automatically adjusts to any voltage between 100–125
and 200–240 volts and either 50 or 60 Hz.
AC voltage: 100–125 volts 200–240 volts
Maximum current: 15.0 A max 7.4 A max
Frequency range: 47/63 Hz 47/63 Hz
Environmental
Operating Non-Operating
Temperature: -5°C to 55°C (23°F to 131°F) -40°C to 85°C (-40°F to 185°F)
Relative humidity: 5% to 95%
(non-condensing)
Maximum altitude: 4.0 Km (13,000 ft) 4.0 Km (13,000 ft)
Safety
IEC 60950 (2nd edition) + A1, A2, A3, A4
IEC 60950 (3rd edition)
UL 60950 (3rd edition)
CAN/CSA C22.2 No.60950-00
VDE (IEC 60950)
CE (73/23/EEC and 93/68/EEC Directive)
China CCC