HP StorageWorks Fabric OS 5.3.0d Release Notes (AA-RWEYH-TE, December 2007)

Important notes
Table 2 provides information relevant to the release.
Table 2 Important release information
Topic Description
ipfilter com
mand
Starting with Fabric OS version 5.3.0, you can use the ipfilter command
to block unauthorized Telnet access. The option to disable Telnet using the
configure command is no longer available.
Use the follow
ing command to create a policy to block Telnet access to any station:
ipfilter --cr
eate blockTelnet -type ipv4 ipfilter
--addrule bl
ockTelnet -sip any -dp 23 -proto tcp -act deny
ipfilter -- a
ctivate blockTelnet
Use the follo
wing command to restore default policies for I Pv4:
ipfilter --a
ctivate default_ipv4 --
See the Fabric OS 5.3.0 command reference guide for mor e information on the
ipfilter command.
PKI cer tication
If you have purchased and installed the Secure Fabric OS option, go
to the following web site for information on obtaining a PKI certicate:
h
ttp://www.hp.com/storage/go/secureos.
FICON sup
port
With release 5.2.0 and later, the Switch Connection Control high integrity
requirement for cascading FICON is available in the standard base Fabric OS.
End users can now de ploy new cascade FICON Directors without purchasing
a separate Secure Fabric OS license.
To add a new F ICON Director into existing casca ded congurations already
running Secured Fabric OS, HP recommends that users continue to deploy
Secure Fabric OS on the new FICON Director instead of migrating to FOS ACL
conguration.
NOTE:
The FC4–48 port Blade is not supported to connect to System z environments
vi a FICON channels or via FCP zLinux on System z. To attach the Direct or
to the System z environment, use a n FC4–16 or FC4–32 Fibre Channel
port Blade.
Diagnostics backport test
Backport tests may be run only in the following congurations:
ApureSANDirector2/128(onlyCP2andFC-16blades)
A SAN Director 2 /128 with no FC4–16 blades installed, using Option 5.
Do not run backport tests in any conguration other than the two listed above;
usetheminicycletestinstead.
Diagnostics spinsilk test
The fol
lowing congurations will pass the spinsilk test:
Apure
SAN Director 2/128 (only CP2 and FC-16 blades)
Apure
4/256 SAN Director, Option 5
Apure
4/256SANDirector,Option5(withFC416blades)
The fo
llowing congurations will fail thespinsilktest;usetheminicycletestinstead:
Amix
ed SAN Director 2/128 (with either CP4 or FC4–16 blades)
Apur
e4/256SANDirector,Option1(apure4/256SANDirectorrefers
to a D
irector with CP4 and FC4–16 bl ad es only).
10