HP StorageWorks Fabric OS 5.3.0d Release Notes (AA-RWEYH-TE, December 2007)

Closed defect summary
Solution
SNMPtrapsrepeatedlysentfromtheswitchevery2secondswhen
port taken out of a fault state implicitly by removing cable or module.
Caused by too ma
ny port ofine SCNs being sent out during port
fault and recover when there is laser fault.
Fixed per Fabric OS 5.3.0
Firmware downgrade to Fabric OS 5.1 or earlier is blocked even
after ports 256 384 are removed from DCC policy created using
[*] option. Currently have to delete DCC policy to avoid this.
Fixed per Fabric OS 5.3.0
Admin user account with permissions to only Admin Domain 255
can create Admin Domains, but only Admin user accounts with
permissions for all Admin D omains should be able to do this.
Fixed per Fabric OS 5.3.0
Conrmatio
n dialog doesn’t appear when name server table closed
by clicking
the “X” but ton. User experiences unexpected close when
clicking
X” button.
Fixed per Fabric OS 5.3.0
Detailed view of any device doesn’t refresh properly when Auto
refresh option is selected & user resizes/scrolls the window.
Fixed per Fabric OS 5.3.0
Role name, and sometimes user name, missing from error message
when user exits from a Telnet session.
Fixed per Fabric OS 5.3.0
The 2/16v switch produces ARB(vc) ll words instead of idles which
could cause failures with certain long distance devices when running
Fabric OS
5.2 with the following port conguration:
nl
portcfglongdistance <port> LS 1 50
nl
portcfgislmode <port> 1
Fixed per Fabric OS 5.3.0
Web Tools not correctly reecting physical switch state of a
persistently disabled switch when the switch is fastbooted. LEDs are
shown unlit instead of slowly blinking yellow.
Fixed per Fabric OS 5.3.0
No event
is generated when the IP address of a switch is changed,
so user can’t determine IP address of the switch was changed by
issuing the command errdump or errshow because IP address
change event was not registered.
Fixed per Fabric OS 5.3.0
Several issues observed in ZoneAdmin and in Admin Domain when
switch is congured in PID format 2, including being unable to see
ports 16-32.
Fixed per Fabric OS 5.3.0
During stress testing, a signicant delay in trafccomingback
from a Fibre Channel Router (FCR) failure in fully redundant SAN
conguration was seen, as trafc temporarily stopped before taking
redundant path after rebooting one of the FCRs in dual back bone
fabric.
Fixed per Fabric OS 5.3.0
During stress testing, sw itch may report fabric busy following issuance
of a
long string of operations repeatedly.
Fix
ed per Fabric OS 5.3.0
When using interactive mode to execute pathinfo,butwithan
invalid source port value, there is no error message.
Fixed per Fabric OS 5.3.0
After receiving login reject on FC4-16IP, subsequent login attempts
may fail intermittently under some conditions. This can be avoided
by moving the session back to init state after rejecting a login.
Fixed per Fabric OS 5.3.0
Du
ring stress testing, FC4-16IP may run out of memory if continually
running slotpoweroff/on on multiple FC4-16IP blades for long
period.
F
ixed per Fabric OS 5.3.0
In Secure FOS, Web Tools gets null pointer from java c on sole rather
than the modify dialog to modify description and/or status when
trying to modif y default admin and user accounts.
Fixed per Fabric OS 5.3.0 which now
includes all Secure FOS functionality.
22