HP StorageWorks Fabric OS 5.3.x administrator guide (5697-0244, November 2009)

208 Configuring Directors
Basic blade management
The following sections provide procedures for powering a port blade off and on and for disabling and
enabling a port blade.
Powering port blades off and on
Port blades ship powered on by default.
To power off a port blade:
1. Connect to the switch and log in as admin.
2. Enter the slotPowerOff command with the slot number of the port blade you want to power off.
The slot must exist in the logical switch where you are logged in.
To provide power to a port blade:
1. Connect to the switch and log in as admin.
2. Enter the slotPowerOn command with the slot number of the port blade you want to power on.
The slot must exist in the logical switch where you are logged in.
13 29/29 45/45 61/61 77/77 93/93 109/109 125/125 13/13
12 28/28 44/44 60/60 76/76 92/92 108/108 124/124 12/12
11 27/27 43/43 59/59 75/75 91/91 107/107 123/123 11/11
10 26/26 42/42 58/58 74/74 90/90 106/106 122/122 10/10
9 25/25 41/41 57/57 73/73 89/89 105/105 121/121 9/9
8 24/24 40/40 56/56 72/72 88/88 104/104 120/120 8/8
7 23/23 39/39 55/55 71/71 87/87 103/103 119/119 7/7
6 22/22 38/38 54/54 70/70 86/86 102/102 118/118 6/6
5 21/21 37/37 53/53 69/69 85/85 101/101 117/117 5/5
4 20/20 36/36 52/52 68/68 84/84 100/100 116/116 4/4
3 19/19 35/35 51/51 67/67 83/83 99/99 115/115 3/3
2 18/18 34/34 50/50 66/66 82/82 98/98 114/114 2/2
1 17/17 33/33 49/49 65/65 81/81 97/97 113/113 1/1
0 16/16 32/32 48/48 64/64 80/80 96/96 112/112 0 /0
Table 53 Default index/area extended-edge PID assignment with no port swap (continued)
Port on
blade
Slot
1Idx/Area
Slot
2Idx/Area
Slot
3Idx/Area
Slot
4Idx/Area
Slot
7Idx/Area
Slot
8Idx/Area
Slot
9Idx/Area
Slot
10Idx/Area
switch:admin> slotpoweroff 3
Slot 3 is being powered off
switch:admin>
switch:admin> slotpoweron 3
Powering on slot 3