HP StorageWorks Fabric OS 5.3.x administrator guide (5697-0244, November 2009)

212 Configuring Directors
Table 56 lists the supported configuration options. Table 57 lists configuration options and resulting slot
configurations.
See Table 54 on page 210 for details about the different blades, including their corresponding IDs.
The following sections contain procedures for obtaining chassis information and for configuring Director
domains using the chassisConfig command.
Obtaining slot information
For a SAN Director 2/128 configured as two logical switches, the chassis-wide commands display or
control both logical switches. In the default configuration, SAN Director 2/128 Directors are configured as
one logical switch, so the chassis-wide commands display and control the single logical switch.
To display the status of all slots in the chassis:
Table 56 Supported configuration options
Option Number of
domains
Maximum number
of ports per switch
Supported port
blades
Supported
CP blades
Notes
1 1 128 FC2-16, FC4-16 CP2 or CP4 Option 1 is the
default
configuration
for SAN
Director
2/128.
22 64/64 FC2-16 CP2
5 1 384 FC4-16, FC4-16IP,
FC4-32, FR4-18i,
FR4-48
1
1. L_Ports are not supported on the FC4-48 blade.
CP4 Option 5 is the
default
configuration
option for
4/256 SAN
Director.
Table 57 Chassis configuration options
Option Result
1 One 128-port switch (Blade IDs 4, 17 on slots 1–4, 7–10. Blade ID 5 and 16 on slots
5, 6)
2 Two 64-port switches (Blade ID 4 on slots 1–4, 7–10. Blade ID 5 on slots 5, 6)
5 One 384-port switch (Blade IDs 4, 17, 18, 31, and 36 on slots 1–4, 7–10. Blade ID
16 on slots 5, 6)