HP StorageWorks Fabric OS 5.3.x administrator guide (5697-0244, November 2009)

342 Administering Advanced Performance Monitoring (APM)
The mask is applied to all end-to-end monitors on the port. Individual masks for each monitor on the port
cannot be specified.
Figure 21 Mask positions for end-to-end monitors
To display the current end-to-end mask of a port
Enter the perfShowPortEeMask command.
The end-to-end mask has 12 fields, each with a value of on or off. See the following example of setting and
displaying an end-to-end mask:
Example: Setting and displaying an end-to-end mask
The end-to-end mask is set on slot 1, port 11.
The default EE mask value for an E_Port is:
TxSID = “00:00:00”
TxDID = “ff:00:00”
RxSID = “00:00:00”
RxDID = “00:00:00”
Only the transmit domain is monitored for E_Ports.
To display a monitor
Enter the perfMonitorShow command, as described in ”Displaying monitor counters” on page 347.
Deleting end-to-end monitors
Enter the perfDelEeMonitor command to delete end-to-end monitors. You can delete all monitors or
specific monitors. The following example deletes the end-to-end monitor number 0 on slot 1, port 2:
switch:admin> perfsetporteemask 1/11, “00:00:ff” “00:00:ff” “00:00:ff” “00:00:ff”
The EE mask on port 11 is set and EE counters are reset.
switch:admin> perfshowporteemask 1/11
The EE mask on port 11 is set by application TELNET
TxSID Domain: off
TxSID Area: off
TxSID AL_PA: on
TxDID Domain: off
TxDID Area: off
TxDID AL_PA: on
RxSID Domain: off
RxSID Area: off
RxSID AL_PA: on
RxDID Domain: off
RxDID Area: off
RxDID AL_PA: on
perfsetporteemask 1/2, “00:00:ff” “00:00:ff” “00:00:ff” “00:00:ff”
SID mask DID mask
Transmitted from port
Received by port
AL_PA mask
Area ID mask
Domain ID mask
SID mask DID mask
switch:admin> perfdeleemonitor 1/2, 0