HP StorageWorks Fabric OS 5.3.x administrator guide (5697-0244, November 2009)

404 Configuring and monitoring FCIP tunneling
Where: <slot#> is the slot in which the FR4-18i blade is installed. A slot number is not required for the
400 MP Router.
Example:
3. Enable FC Fastwrite on the ports using the portcfg command.
#portcfg fastwrite <slot#/port_id> —enable
Where <slot#> is the slot in which the FR4-18i is installed. A slot number is not required for the 400 MP
Router.
4. Repeat steps 1 through 3 for the blade or switch on the other end of the FC Fastwrite path.
SJ3_6A1_12000_0:root> fastwritecfg --enable 7
!!!! WARNING !!!!
Enabling FC Fastwrite will require powering off and back on the and it may take
upto 5 minutes. For non bladed system, the switch will be rebooted. Data traffic
will be disrupted.
Continue (Y,y,N,n): [ n] y
SJ3_6A1_12000_0:root> fastwritecfg --disable 7
!!!! WARNING !!!!
Disabling FC Fastwrite will require powering off and back on the and it may take
upto 5 minutes. For non bladed system, the switch will be rebooted. Data traffic
will be disrupted.
Continue (Y,y,N,n): [ n] y
Slot 7 is being powered off