HP StorageWorks Fabric OS 5.3.x administrator guide (5697-0244, November 2009)

418 Configuring and monitoring FCIP tunneling
To verify that a VE_Port or VEX_Port is online
1. Use the switchShow command to view and verify that the FCIP tunnel is online.
switch:admin06> portenable 8/18
switch:admin06> portenable 8/19
switch:admin06> switchshow
switchName:switch
switchType:42.2
switchState:Online
switchMode:Native
switchRole:Subordinate
switchDomain:4
switchId:fffc04
switchWwn:10:00:00:60:69:80:0d:bc
zoning:ON (LSAN001)
switchBeacon:OFF
blade3 Beacon: OFF
blade4 Beacon: OFF
blade8 Beacon: OFF
FC Router:ON
FC Router BB Fabric ID:1
Area Slot Port Media Speed State
=====================================
32 3 0 id N4 Online F-Port 50:03:0d:30:0d:13:00:09
33 3 1 id N4 Online F-Port 50:03:0d:30:0d:13:00:11
34 3 2 id N4 Online F-Port 50:03:0d:30:0d:13:00:13
35 3 3 id N4 Online F-Port 50:03:0d:30:0d:13:00:15
36 3 4 id N2 Online F-Port 21:00:00:e0:8b:08:bd:20
<output truncated>
210 8 18 -- -- Online VE-Port 50:00:51:e3:51:55:3f:1e "fcr_xd_3_16"
(downstream)
211 8 19 -- -- Online VE-Port 50:00:51:e3:70:42:5f:76 "fcr_xd_5_17"
(downstream)
<output truncated>
223 8 31 -- -- Offline
8 ge0 id 1G Online
8 ge1 id 1G Online