HP Application Recovery Manager software A.06.10 Administrator's guide (March 2008)

SMI-S Agent is always started as an administrator’s process on the application and
backup systems. Therefore, the user who starts it must be the member of admin or
operator user groups.
Action
Using the GUI, check if the user is a member of admin or operator user groups. If
not, add the user to one of these groups. In addition, ensure that administrators from
both the application and backup systems belong to Application Recovery Manager
admin or operator.
Problem
On HP-UX, SMI-S Agent fails to communicate with the HP StorageWorks SMI-S EVA
provider using SSL
[Warning]
The SSL connection to the StorageWorks EVA SMI-S provider has failed.
The error description returned is:
SSL Exception: Random seed file required
On HP-UX systems, Pegasus libraries require the random number generator pseudo
device for its SSL-based communication with the SMI-S provider. If the pseudo device
is not present, the warning appears.
Action
1. Install the pseudo device in /dev/random on the HP-UX backup system.
2. Re-run the session.
Problem
No HP StorageWorks SMI-S CIMOM login entries are configured within SMISDB
Action
Add an HP StorageWorks SMI-S CIMOM login information to SMISDB:
omnidbsmis -ompasswd -add hostname [-ssl] [-port port_number]
[-user username] [-passwd password] [-check [-host hostname]]
Problem
On the application system, dismounting a filesystem fails
Troubleshooting58