HP Application Recovery Manager software A.06.10 Administrator's guide (March 2008)

Action
1. In the backup specification, specify an existing and configured LDEV/MU# on
the backup system, or ensure that LDEV/MU# stated in the output is not set in
the XP LDEV exclude file.
2. Restart the session.
Problem
In some initial configurations on windows, filesystems may not be resolved on the
backup system. The filesystem does not show up at all, even with manual pair or
split.
Action
Uninstall the XP disk from the device manager and rescan the system.
Instant recovery problems
Problem
Instant recovery session fails if the application system is in cluster
[Critical] From: SSEA@machine.company.com "" Time: 11/8/2001 11:43:09 AM
Data consistency check failed!
Configuration of volume group /dev/vg_sap has changed since the last
backup session!
The problem occurs if the option Check data configuration consistency is selected
and may be caused by:
Failover to a secondary node
Changed volume group configuration on the application system
Action
Ensure that the volume group configuration on the application system has not changed
and/or deselect Check the data configuration consistency, and then restart instant
recovery.
Administrator's guide 89