Brocade Web Tools Administrator's Guide (53-0000194-01, November 2006)

13-8 Web Tools Administrator’s Guide
Publication Number: 53-0000194-01
13
4. Click the alarm area report to be viewed from the Area Selection menu.
5. Click the Configuration Report subtab.
This tab displays a report of the configuration for the selected area.
Displaying Alarms
Using the Alarm Notification tab, you can view a list of all alarms that have occurred for a selected
class/area (see Figure 13-1 on page 13-2). Table 13-1 describes the columns in this report. (Note that for
the FRU class, only the Name, State, and Time columns are displayed. In addition, if the FRU area is
Fan, the Name column refers to either a fan or a fan FRU, depending on the switch model. See
“Displaying Detailed Fan Hardware Status” on page 12-5 for more information.)
To view alarms
1. Launch the Fabric Watch module as described on page 13-3.
2. Click the class that you want to check for alarms in the Fabric Watch navigation tree.
3. Click the Alarm Notification tab.
4. Click the area that you want to check for alarms from the Area Selection menu.
All alarms for that area display.
For troubleshooting responses to alarms, see the Fabric Watch Administrator’s Guide.
Table 13-1 Alarm Notification Table Fields
Field Description
Name The string assigned to the element that had an event
State The current state of the element
Reason The event type that was triggered
Last Value The data value of the element when the event was triggered
Current Value The current data value of the element
Time Time when the event occurred