HP StorageWorks Fabric OS 5.2.3 Release Notes (AA-RWEYD-TE, November 2007)

portcfgdefault
command function change
for the Brocade 4Gb SAN
Switch for HP c-Class
BladeSystem
With Fabric OS 5.2.1b, the portcfgdefault command now resets the
conguration to HP factory default port settings.
Update to Brocade 4Gb
SAN Switch for HP c-Class
BladeSystem instructions.
After connecting to the Brocade 4Gb SAN Switch via the Onboard
Administrator (OA) connect command, you will be in the switch CLI prompt.
To return to th e OA serial prompt:
Type Exit to log out of the switch.
Press Shift-Ctrl-underscore (escape sequence) to return to the OA prompt.
Zoning considerations with
FC4–48 blade
B-Series switches running pre-5.2.0 rmware do not accept zone databases
with Domain, Port Index, references to p orts higher than 255. Zoning in Fabric
OS 5.2.0 and later, therefore, do not allow a Domain, Por t Index entry for
ports above 255 to be created unless all switches in the fabric are at
Zoning considerations continued...
Fabric OS 5.2.0 or later versions. Once such an entry has been put into
the zone database, an attempt to connect a pre-Fabric OS 5.2.0 switch to
the fabric results in that switch being segmented with a Zone Mismatch
segmentation reason.
Any zoning that is already in use can continue to be used. H owever, in Fabrics
containing pre-Fabric OS 5.2.0 switches, if new devices are added on the
upper 16 ports (ports 32-47) of the FC4-48 port blade, then WWN zoning
has to be used for those devices. If there is an existing Domain Port Index
zone that connects to ports 32–47, HP recommends that you transform just
that zone to WWN zoning. This would minimize the likelihood of rebuilding
theentirefabric.
Fabrics containing only Fabric OS 5.2.0 and later switches have no zoning
limitation.
Fabric OS 5.2 .1 xes
Table 3 lists defects closed in the Fabric OS 5.2.1 rmware release.
Table 3 Fabric OS 5.2.1 closed defects
Closed d e fect summary
Solution
4/256 director running FICON with fsmode enabled panics after
upgradefromFOSv5.0.x,toeitherv5.1.xorv5.2.0.
Fixed per Fabric OS 5.2.1.
After
previous diag failure, 2/128 director LEDs may blink indicating
a failure on subsequent diag command execution, even though
slotshow command shows proper operation.
Fixe
dperFabricOS5.2.1.
FR4-18i router blade POST failed after slotpoweroff/on.
Fixed per Fabric OS 5.2.1.
Error messages may result after a lot of diagnostic tests run during
warm recovery on standby.
Fixed per Fabric OS 5.2.1.
Switch panics in rare cases during HAfailover d ue to zoning daemon
assertion.
Fixed per Fabric OS 5.2.1.
Panic observed on new active CP after HAfailover, running I/O
through AD, mirrored port and FC4-48.
Unlikely user scenario
nl
Fixed per Fabric OS 5.2.1.
Fastboot on remote switch followed by HAfailover on 4/256 can
cause multiple kernel panics & error messages.
Unlikely user scenario
nl
Fixed per Fabric OS 5.2.1.
When using continuous mod e in Fabric Watch with timing interval of
1 second, too many e-mail alert messages can cause unexpected
termination of other processes.
Fixed per Fabric OS 5.2.1.
HP StorageWorks Fabric OS 5.2.3 release notes