HP StorageWorks Fabric OS 5.2.3 Release Notes (AA-RWEYD-TE, November 2007)

If failover occurs while FC4-48 blades being slotpoweron, some
E-ports and unused ports may get stuck at Mod_Val state.
Fixed per Fabric OS 5.2.1.
Core le ffc_data is generated after disable/enable switch.
Fixed per Fabric OS 5.2.1.
swNbEntry under swFabric omits display of trunked EX-port ISLs.
Fixed per Fabric OS 5.2.1.
After congdownload and reboot, portshow displays FCIP tunnel for
an IPIF that does not exist on the GE.
Fixed per Fabric OS 5.2.1.
In Mixed Fabric AD Context, EnumerateInstances/EnumerateInstance-
Names/ExecQuery (Brocade_SwitchFcPort) is returning SwitchFCPort
Instances of N
ON v5.2.0 FOS Switches.
Fixed per Fabric OS 5.2.1.
Supportsave not marking all local tracedump lesasFTPedconsistently
after supportsave transfer completed.
Fixed per Fabric OS 5.2.1.
Porterrshow shows Slot and Port for chassis based systems, but should
show in slot/port format.
Fixed per Fabric OS 5.2.1.
QuickLoop is
not supported on Fabric OS 5.2, so Web Tools should
grey out but
tons to create it .
Fixed per Fabric OS 5.2.1.
MPR 400 faults during power up.
Fixed per Fabric OS 5.2.1.
Portenable does not enable the "Disabled (Insufcient frame buffers)"
port even after portcfglongdistance command is issued to
reduce the distance to get within enough buffer.
Fixed per Fabric OS 5.2.1.
After delet
ing many user accounts (150) from Web Tools, it loses
connectio
ntotheswitch.
Fixed per Fabric OS 5.2.1.
ipperf reports h igher (double/triple) loss rates when running over
impaired WAN link.
Fixed per Fabric OS 5.2.1.
High availability of transferred supportsave les not ensured with
current implementation.
Fixed per Fabric OS 5.2.1.
VE port goe
sdownandthencomesupwithtwotunnelsof500MB
each and compression turned ON. I/O is resumed when the VE por t
comes back up.
Fixed per
Fabric OS 5.2.1.
If Linux magic debug sequence "sysrq" is not disabled by default,
switch may restart/kill tasks/umount disks.
Fixed per Fabric OS 5.2.1.
Error message occurs after set ting 4/256 speed to 1Gbps.
Fixed per Fabric OS 5.2.1.
If ports a
re disabled from the edge fabric, the unused bb x late domain
is preserved to prevent disruption in the bb fabric. However, after
HA failover the BB xlate domain is not preserved, potentially causing
fabric r
econguration in the backbone.
Fixed per Fabric OS 5.2.1.
Using powerslotoff command to turn off a blade, switch view in W eb
Tools shows the slot is vacant but the temperature status still displays
the temperature of the blad e.
Fixed per Fabric OS 5.2.1.
Unexpected messages seen when DHCP is turned ON/OFF, but DHCP
still gets enabled/disabled.
Fixed per Fabric OS 5.2.1.
Hosts lost access to storage due to la ck of buffer credits to transmit
frame
soverparticularVC.
Fixed
per Fabric OS 5.2.1.
Warning dialogue appears after modifying an AD and neither saving
it nor applying it, then switching the AD context from the switch
explorer window, then closing the expired AD window.
Fixed per Fabric OS 5.2.1.
Ex_port trunks attached to edge switches running Fabric OS 3.2.0
rmware fail to recover after fastboot of FCR switches.
Fixed per Fabric OS 5.2.1.
Persistently disabled port will be enabled after switchenable in FICON
mode, but should not be.
Fixed per Fabric OS 5.2.1.
18