HP StorageWorks Fabric OS 5.2.3 Release Notes (AA-RWEYD-TE, November 2007)

Non-disruptive congdownload may fail if invalid threshold alarm
lter is used, due to invalid value.
Fixed per Fabric OS 5.2.1.
On 4/256, movin
g the sw itch PID to 2 , waiting for the fabric to
stabilize, and then issuing hafailover causes an assert on the new
active CP.
Fixed per Fabr
ic OS 5.2.1.
Redundant message about Ex_port trunking resulted from checking
system settings for rmwaredownload Fabric OS 5.2.0 to 5.1.0d.
Fixed per Fabric OS 5.2.1.
Portperfshow command does not display trafconcongured VE
tunnel. However, issuing the portstatsshow <port> command
displays the trafc.
Fixed per Fabric OS 5.2.1.
Downloading a cong le that contains only Fabric Watch parameters
incorrectly
fails when header and termination labels are absent.
Fixed per Fab
ric OS 5.2.1.
After MPR 400 shut down, the other side of VE links on a 4/256 still
has stale/uncompleted info of VE links on switchshow.Fabricshow
still has some incomplete info from the MPR 400.
Fixed per Fabric OS 5.2.1.
In User Dened AD [Device members]/ADO, inconsistencies observed
for GiGE Port Details.
Fixed per Fabric OS 5.2.1.
When pathin
fo CLI is used in interactive mode with extended stats,
reverse pa
th and strict source route an error is returned if hop count
given is le
ss than total hop count required to reach destination domain
plus the re
verse path.
Fixed per Fabric OS 5.2.1.
Disabling and enabling a trunk master on a 4/256 causes 4/16
switch on other side of the ISL to be stuck at Port_Flt. N ot likely in user
scenario as this was found in stress-to-fail testing.
Fixed per Fabric OS 5.2.1.
In Web Tools, if user tries to congure the port speed th rough port
admin services window for FC4-48 port, the port is also getting
aggedaslockedG-portwhenobservedthroughportcfgshow
CLI. No impact to functionality.
Fixed per Fabric OS 5.2.1.
On 4/256
,rtedebugclireturnserror"REASON:ROUTE_ABSENT"for
adevic
e connected to FC4-48 port blade during stress testing.
Fixed per Fabric OS 5.2.1.
When multiple API clients try to get default zone mo de at the same
time, core les can b e generated by the common access layer daemon
on the switch.
Fixed per Fabric OS 5.2.1.
Port Zoning view displays the info when a user refreshes AD
information from the fabric. AD membership information in the ZET is
broken for the refr esh operation on the Port Zoning view.
Fixed per Fabric OS 5.2.1.
Inserting an FC4 -48 blade into a pre-Fabric OS 5.2 chassis
(unsupported) causes FAULTY(1) error that will not clear with blade
removal.
Fixed per Fabric OS 5.2.1.
When host PC uses the Java plugin 1.4.2_08, the event time lter is
ltering on the basis of AM time when PM time is provided in "TO"
eld.
Fixed per Fabric OS 5.2.1.
The supportsave commandfailswithillegaloption-ssavingCORE
FFDC.
Fixed per Fabric OS 5.2.1.
RCSDpanicduringzoneactivationon4/32duetosharedmemory
all
ocation failure.
Fi
xed per Fabric OS 5.2 .1.
If HBA sends previously assigned PID in the SID of the FLOGI on ports
32-47 on the FC4-48 port blade will come up as a g-port.
Fixed per Fabric OS 5.2.1.
Some operations initiated from Fabric Manager, Web Tools, and/or
SMI-A will fail if the system switch is running Fabric OS v5.2.0a for
more than 30 days.
Fixed per Fabric OS 5.2.1.
HP StorageWorks Fabric OS 5.2.3 release notes