Brocade Network Advisor SAN User Manual v11.1x (53-1002167-01, May 2011)

Brocade Network Advisor SAN User Manual 959
53-1002167-01
# CONSRV Events Table
B
# CONSRV Events Table
# Thermal Event Reason Codes Table
Event Reason Code FRU Code/Event Type Description Severity
504 DVP/LIM/HW M-EOS: Port module failure. 3
506 DVP/PORT Fibre Channel port failure 3
509 DVP/PORT Fibre Channel path failure. 0
511 LIM/DVP LIM SPP failure. 3
514 DVP/ LIM/PORT SFP/XFP optics failure. 3
517 LIM LIM SPP Offline. 3
530 LIM/DVP LIM Power-up diagnostic failure. 3
536 LIM/DVP Internal Frame Error port anomaly - threshold exceeded. 2
604 SBAR/SWM/HW M-EOS: SBAR module failure. 3
607 SBAR/SWM/HW M-EOS: Switch contains no operational SBAR cards. 4
610 SWM/INFO SWM BMAC Link Down. 0
622 SBAR/INFO SWM powered off 0
625 SBAR/INFO SWM NV RAM failure. 0
Event Reason Code FRU Code/Event Type Description Severity
800 DVP/LIM/HW High temperature warning. 3
801 DVP/LIM/HW Critically hot temperature warning. 3
802 DVP/LIM/HW M-EOS: Port card shutdown due to thermal violations. 3
805 SWM/SBAR/HW High temperature warning. 3
806 SWM/SBAR/HW Critically hot temperature warning. 3
807 SWM/SBAR/HW M-EOS: SBAR module shutdown due to thermal violations. 3
810 CTP/HW High temperature warning. 3
811 CTP/HW Critically hot temperature warning. 3
812 CTP/HW CTP shutdown due to thermal violations. 3
850 CTP/HW System shutdown due to CTP thermal threshold violations. 4