Brocade Network Advisor SAN User Manual v11.1x (53-1002167-01, May 2011)

1124 Brocade Network Advisor SAN User Manual
53-1002167-01
Database tables and fields
E
RX_UTILIZATION 'The computed value of RX based on speed of port double
precision
LINK_FAILURE Count of link failures. This count is part of the Link
Error Status Block (LESB). (FC-PH 29.8). Note, this is
a Fibre Channel only stat
double
precision
TX_LINK_RESETS Count of Link resets. This is the number of LRs
received. Note, this is a Fibre Channel only stat
double
precision
RX_LINK_RESETS Count of Link resets. This is the number LRs
transmitted. Note, this is a Fibre Channel only stat
double
precision
SYNC_LOSSES Count of instances of synchronization loss detected
at port. This count is part of the Link Error Status
Block (LESB). (FC-PH 29.8). Note, this is a Fibre
Channel only stat.
double
precision
SIGNAL_LOSSES Count of instances of signal loss detected at port.
This count is part of the Link Error Status Block
(LESB). (FC-PH 29.8). Note, this is a Fibre Channel
only stat
double
precision
SEQUENCE_ERRORS Count of primitive sequence protocol errors detected
at this port. This count is part of the Link Error Status
Block (LESB). (FC-PH 29.8). Note, this is a Fibre
Channel only stat
double
precision
INVALID_TRANSMISSIONS Count of invalid transmission words received at this
port. This count is part of the Link Error Status Block
(LESB). FC-PH 29.8). Note, this is a Fibre Channel
only stat
double
precision
CRC_ERRORS Count of frames received with invalid CRC. This count
is part of the Link Error Status Block (LESB). (FC-PH
29.8). Loop ports should not count CRC errors
passing through when monitoring. Note, this is a
Fibre Channel only stat.'
double
precision
LAST_UPDATE_TIME Time when this stats record was updated timestamp
TABLE 366 SWITCH_TE_PORT_PERFORMANCE
Field Definition Format Size
PORT_ID Primary key of the Switch Port int
SWITCH_ID Primary key of Virtual Switch which this port is
present
int
TX The number of octets or bytes that have been
transmitted by this port. One second periodic polling
of the port. This value is saved and compared with
the next polled value to compute net throughput.
Note, for Fibre Channel, ordered sets are not
included in the count.
double
precision
TABLE 365 SWITCH_PORT_PERFORMANCE (Continued)
Field Definition Format Size