Brocade Network Advisor SAN User Manual v11.1x (53-1002167-01, May 2011)

Brocade Network Advisor SAN User Manual 415
53-1002167-01
Virtual Fabrics requirements
17
Virtual Fabrics requirements
To configure Virtual Fabrics, you must have at least one Virtual Fabrics-enabled physical chassis
running Fabric OS 6.2.0 or later in your SAN. Use one of the following options to discover a Virtual
Fabrics-enabled physical chassis on the Management application topology:
Discover a Virtual Fabrics-capable seed physical chassis running Fabric OS 6.2.0 or later.
Virtual Fabrics is disabled by default. This physical chassis displays as a legacy switch. Once
discovered, you must enable Virtual Fabrics.
Discover a Virtual Fabrics-enabled seed physical chassis running Fabric OS 6.2.0 or later with
Virtual Fabrics enabled, and at least one logical switch defined on the core switch. The physical
chassis displays as a virtual switch.
Upgrade a physical chassis already in your SAN to Fabric OS 6.2.0 or later. Virtual Fabrics is
disabled by default. This switch displays as a legacy switch. Once upgraded, you must enable
Virtual Fabrics.
For more information about enabling Virtual Fabrics on a physical chassis, refer to “Enabling Virtual
Fabrics on page 417.
Table 31 lists the Virtual Fabric-capable physical chassis and the number of logical switches
allowed for each of those physical chassis.
For the switches, any port can be assigned to any logical switch. However, depending on the
partition type, the backbone chassis have the port requirements shown in Table 32.
TABLE 31 Maximum number of logical switches per chassis
Physical chassis Number of logical switches allowed
40-port, 8 Gbps FC Switch 3
80-port, 8 Gbps FC Switch 4
48-port, 16 Gbps FC Switch 4
1
1. The maximum is 3 logical switches if you are using FC-FC routing.
384-port Backbone Chassis 8
192-port Backbone Chassis 8
TABLE 32 Blade and port types supported on logical switches for backbone chassis
Logical switch type Ports
Default logical switch Extension Blade—E_, F_, GE_, and VE_Ports
FC 10-6 ISL Blade—E_ and F_Ports
FC 8 GB Port Blade—E_ and F_Ports
FC 16 GB Port Blade—E_ and F_Ports
10 Gig FCoE port Blade—E_ and F_Ports
8 Gbps Extension Blade
FC ports: E_, F_, and VE_Ports
GE ports: VE_Ports
384-port and 192-port Backbone Chassis— ICL ports