Data Center Fabric Manager Enterprise User Manual v10.3.X (53-1001357-01, November 2009)

376 DCFM Enterprise User Manual
53-1001357-01
Configuring an FCIP tunnel
12
3. Click the Add Tunnel button, or right-click on the switch and select Add Tunnel.
The Add FCIP Tunnel dialog is displayed (Figure 136). The name of the switch you selected is
displayed in the Switch field under Switch One Settings. This dialog allows you to configure
settings for both switches on either end of the tunnel.
FIGURE 136 Add FCIP Tunnel dialog box
4. Click Select Switch Two under Switch Two Settings to display discovered extension switches,
and select the switch that you want to connect to switch one.
The switch name and fabric are displayed in the Switch and Fabric fields.
5. Enter a description of the tunnel in the Description field.
NOTE
You cannot assign a Tunnel ID until after at least one circuit is configured. The Add Circuit
dialog returns you to the Add FCIP Tunnel dialog to allow you to select the Tunnel ID.
6. Select Add Circuit.
The Add FCIP Circuit dialog is displayed. Continue with Adding an FCIP circuit”.