Enabling a CEE port or LAG
13
6. Select at least one available CEE port from the Available Members table and click the right
arrow button to move them to the LAG Members table.
The CEE ports are now part of the link aggregation group.
7. Continue to configure the following LAG parameters. These parameters are disabled until you
add a CEE port to the LAG members table.
Mode - The ports that are LAG members are in either Static or Dynamic mode. You can
change the mode of new port members only; you cannot change the mode on existing
members of a LAG.
If the mode is set as Dynamic, you can change the dynamic mode type (to Active or
Passive) only for newly-added ports, not for existing port members of a LAG.
Type - The type value options are Standard, where the LAG is limited to 16 ports, and
Brocade, where the LAG is limited to four ports. The default is Standard. The type is set
when you add a LAG; you cannot edit the type using the Edit LAG dialog box.
8. Click OK when you have finished modifying the LAG parameters.
The CEE Confirmation and Status dialog box displays.
9. Review the changes carefully before you accept them.
10. Click Start to apply the changes, or click Close to abort the operation.
Enabling a CEE port or LAG
If you select multiple switches or multiple ports and LAGs from two or more switches, both the
Enable button and the Disable button are disabled.
1. Select Configure > CEE Switch > CEE from the menu bar.
The CEE Configuration dialog box displays, showing the status of all CEE-related hardware and
functions.
2. Select the CEE port or link aggregation group (LAG) that you want to enable.
NOTE
All selected LAGs must be in the same state (enabled or disabled); otherwise, both the Enable
and Disable buttons are disabled.
3. Click Enable.
The selected CEE port or LAG is enabled for CEE configuration.
4. Click OK.
The CEE Confirmation and Status dialog box displays.
5. Review the changes carefully before you accept them.
6. Click Start to apply the changes, or click Close to abort the operation.
The selected CEE port or LAG is enabled for CEE configuration. (The Status column in the CEE