Data Center Fabric Manager Enterprise User Manual v10.3.X (53-1001357-01, November 2009)

DCFM Enterprise User Manual 533
53-1001357-01
Virtual Fabric requirements
17
For more information about enabling Virtual Fabrics on a physical chassis, refer to “Enabling Virtual
Fabrics on a discovered device” on page 535.
The following table lists the Virtual Fabric-capable physical chassis and the number of logical
switches allowed for each of those physical chassis.
For the 40-port, 8 Gbps FC Switch and the 80-port, 8 Gbps FC Switch, any port can be assigned to
any logical switch. However, depending on the partition type, the backbone chassis have the
following port requirements.
Physical chassis Number of logical switches allowed
40-port, 8 Gbps FC Switch 3
80-port, 8 Gbps FC Switch 4
384-port Backbone Chassis 8
192-port Backbone Chassis 8
Logical switch type Ports
Default logical switch Extension Blade—E_, F_, GE_, and VE_Ports
Application Platform Blade—E_ and F_Ports
FC 10-6 ISL Blade—E_ and F_Ports
Encryption Blade—E_, F_, and Encryption ports
FC 8 GB Port Blade—E_ and F_Ports
10 Gig FCoE port Blade—E_ and F_Ports
8 Gbps 12-FC port, 10 GbE ports, 2-10 GbE ports extension Blade
FC ports: E_, F_, and VE_Ports
GE ports: VE_Ports
384-port and 192-port Backbone Chassis— ICL ports
Logical switch
Extension Blade—GE_ and VE_Ports
FC 8 GB Port Blade—E_ and F_Ports
8 Gbps 12-FC port, 10 GbE ports, 2-10 GbE ports Extension Blade
FC ports: E_, F_, and VE_Ports
GE ports: VE_Ports
Base switch
Extension Blade—GE_ and VEX_Ports
FC 8 GB Port Blade—E_ and EX_Ports
8 Gbps 12-FC port, 10 GbE ports, 2-10 GbE ports extension Blade
FC ports: E_, EX_, VE_, and VEX_Ports
GE ports: VE_Ports
384-port and 192-port Backbone Chassis— ICL Ports