Data Center Fabric Manager Enterprise User Manual v10.3.X (53-1001357-01, November 2009)

DCFM Enterprise User Manual 637
53-1001357-01
Appendix
B
Call Home Event Tables
In this appendix
This section provides information about the specific events that display when using Call Home. This
information is shown in the following Event Tables.
Call Home Event Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 637
# CONSRV Events Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 639
# Thermal Event Reason Codes Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 639
# Brocade Events Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 640
Call Home Event Table
Event Reason Code FRU Code / Event Type Description Severity
N/A Ethernet Event Management application unable to reach Switch. 0
10 None/SW Login Server unable to synchronize databases. 2
11 None/SW Login Server database found to be invalid. 2
20 None/SW Name Server unable to synchronize databases. 2
21 None/SW Name Server database found to be invalid. 2
40 None/SW Operator panel has failed. 2
50 None/SW Management Server unable to synchronize databases. 2
51 None/SW Management Server database found to be invalid. 2
60 None/SW Fabric Controller unable to synchronize databases. 2
61 None/SW Fabric Controller database found to be invalid. 2
82 CTP/SW Port is blocked by port fencing. 0
86 None/Info Continuous Incident detection and Reporting CIDR threshold value
exceeded.
0
90 None/SW Database replication time out. 2
92 BKP/HW Backplane NVRAM failure. 3
200 None/SW Power supply AC voltage failure. 3
201 PWR/HW Power supply DC voltage failure. 3
202 PWR/HW Power supply thermal failure. 3