HP StorageWorks Fabric OS 5.3.0b Release Notes (AA-RWEYF-TE, October 2007)

HA
If there is an already segmented port and backbone devices are exported to
an edge fabric, a build fabric/fabric reconguration can occur after running
haFailover. Ensure that there no segmented port exist before upgrading
rmware.
IPSec for B-Series MP
Router Blade (FR4–18i)
IPSec implem
entation details:
Pre-shared k
ey
•Mainmode(I
KE negotiation protocol)
•Tunnelmode
in Encapsulating Security Payload (ESP)
IPSec speci
c statistics not provided.
No NAT or IP
V6 support
FastWrite
and Tape Pipelining will not be supported in conjunction with secure
tunnels.
Jumbo fra
mes will not be supported on secure tunnels.
ICMP red
irect is not supported for IPSec-enabled tunnels.
Only a si
ngle secure tunnel will be allowed on a port. Non-secure tunnels will
not be al
lowed on th e same po rt as secure tunnels.
Modify
operations are not allowed on secure tunnels. To change the
conguration of a secure tunnel, you must rst delete the tunnel and then
re-create it with the desired options.
Onlyasinglerouteissupportedonaninterfacewithasecuretunnel.
An IPSec tunnel cannot be created using the same local IP address if ipperf is
active and using the sam e local IP add ress (source IP address).
Unidirectional supported throughput is ~104Mbytes/sec and bidirectional
sup
ported throughput is ~90Mbytes/sec.
An I
PSec tunnel takes longer to come online than a non-IPSec tunnel.
Fabric Merge
Do not try to merge fabrics with conicting domain IDs over a VE_Port. Before
merging two fabrics over FC-IP with VE_Ports at each end, HP recommends that
all domain ID and zoning conicts be resolved.
Scalability
Support for Default Zoning policies has been added to Fabric OS 5.1.0.
Typically, when you issue the cfgDisable command in a large fabric with
thousands of devices, the name server indicates to all hosts that they can
communicate with each other. To ensure that all devices in a fabric do not see
each other during a cfgDisable operation, you can activate a Default Zone
with policy set to no access. If Default zoning policies show enabled, all
cfgEnable/disable commands and zoning changes must be run from a
switch in the fabric running Fabric OS 5.1.0/5.2.0a.
In large fabrics with more than 1,0 00 ports, HP recommends that the MS
Platform Database be disabled. The Platform DB must also be disabled before
downgrading to earlier versions of Fabric OS. This can be done using the
msPLMgmtDeactivate command.
FRU insertion
The FW_FRU_INSERTED message is displayed twice when a power supply FRU
is inserted and powered on. There is no functional impact.
System boot
Not all Fabric OS services run when the prompt becomes available during boot
up. Wait for all the services to come up before using the switch or performing
zoning actions.
Performance Monitoring
If the user tries to save more than 512 monitors using the perfCfgSave
command, some of the monitors may be lost.
Management P roxy
switches
If you using a Fabric OS 4.x switch as an API or SMI-S proxy to manage a 5.1.0
switch, you must be running Fabric OS 4.4.0d.
HP StorageWorks Fabric OS 5.3.0b release notes
13