HP StorageWorks Fabric OS 5.3.0b Release Notes (AA-RWEYF-TE, October 2007)

Fabric OS 5.3.0 xes
Table 3 lists defects closed in the Fabric OS 5.3.0 rmware release.
Table 3 Fabric OS
5.3.0 closed defects
Closed defect summary
Solution
4/256 Director r
unning FICON with fsmode enabled & D LS on an d
port based route policy panics after upgrade from Fabric OS 5.0.x to
5.1.x or 5.2.0.
Fixed per Fabri
c OS 5.3.0
Kernel Ops error when counter is overrun during stress to fail test.
Fixed per Fabric OS 5.3.0
Exception error on 4/256 can occur when performing port mirroring
causing reboot.
Fixed per Fabric OS 5.3.0
Tstimezone command doesn’t show correct time and date if
configdownload interface is used to update timezone.
Fixed per Fabric OS 5.3.0
After executing trunk disable/ enab le on all edge switches in large
scalability fabric, a 2/128 E_port becam e stuck in Loopback mo de.
Fixed per Fabric OS 5.3.0
Admin Domains enforcement on SID/DID not performed.
Portmirror allowed addition of mirror port in Admin Domain3
when SID and DID were not port members.
Fixed per Fabric OS 5.3.0
New active CP
got Oops and reboot during initialization after
hafailover
command issued.
Fixed per Fabric OS 5.3.0
After CP reboot, VE tunnel doesn’t come up due to GE0 port on
FR4-18i stuck in No_Sync state when using copper SFP’s.
Fixed per Fabric OS 5.3.0
Switch doesn’t generate RSCN following zoning changes using
cfgEnable in interop mode, resulting in no PLOGI from hosts, and
no target discovery.
Fixed per Fabric OS 5.3.0
When more than the supported number of Ex_Ports attached to same
edge fabric with FCR switches, switch may panic causing continuous
rebooting.
Fixed per Fabric OS 5.3.0
When more tha n the supported number of intelligent blades (FR4-18i,
FC4-16IP, etc) conguredin4/256,poweringupthe4thand5th
blades at the same time results in a failover.
Fixed per Fabric OS 5.3.0
In rare occurrence, FR4-18i Blade could become faulty after rmware
download and slotpoweron followed by slotpoweroff.
Fixed per Fabric OS 5.3.0
Tape backup job failures occasionally observed in congested IO
conditions due to tape pipelinin g not properly handling target
recovery.
Fixed per Fabric OS 5.3.0
After changing FID & enabling FCR switch, all connected/active
ports remain disabled.
Fixed per Fabric OS 5.3.0
If active CP fails over after FC4-16ip port Blade runs slotpower on,
all the FC4-16ip iSCSI ports can get stuck at “No_Sync” while FC
ports come online.
Fixed per Fabric OS 5.3.0
After an all switches disable on 4 /256 with FC4-48 port blades,
standby CP asserted and rebooted.
Fixed per Fabric OS 5.3.0
HAfailover during FCIP IO through IPSec enabled tunnel
sometimes causes VE port to go down, then come back up.
Fixed per Fabric OS 5.3.0
User was able to congure isns client via isnsccfg to communicate
with isns server through a port on FR4-18i, but this will not work (nor
should it).
Fixed per Fabric OS 5.3.0
HP StorageWorks Fabric OS 5.3.0b release notes
17