Brocade Fabric OS v6.4.3f Release Notes v1.0

Close with Code Change in Fabric OS v6.4.1a
Fabric OS v6.4.3f Release Notes v1.0 Page 106 of 149
Defect ID: DEFECT000303239
Technical Severity: High
Summary: Observed fspf daemon termination when performing portenable of E-ports in a FCR setup
with FCIP VEX links.
Symptom: After port disable/enable or cable pull disruptive testing, observe some switches are not
present in fabricshow, some VEx ports remain disabled (Switch not ready for EX_Ports)
Feature: FC Services
Function: FSPF
Probability: Medium
Found in Release: FOS6.4.0
Where Else Fixed: FOS6.4.1_fcoe, FOS6.4.1 a
Defect ID: DEFECT000315822
Technical Severity: High
Summary: SNMPd is killed and not restarted
Symptom: When the configured trap IP address does not match configured access control list, SNMP
is killed after some run time and it is not restarted.
Feature: Mgmt Embedded - SNMP
Function: Other
Probability: Low
Found in Release: FOS6.4.1_fcoe
Where Else Fixed: FOS6.4.1 a
Defect ID: DEFECT000318549
Technical Severity: High
Summary: FCIP tunnel bounces during hafailover
Symptom: While performing hafailover testing with heavy traffic load, occasionally observed frame
drops and FCIP tunnel bounce caused by setting of GE mode during hafailover
Feature: FCIP
Function: FCIP HA
Probability: Medium
Found in Release: FOS6.4.0
Where Else Fixed: FOS6.4.1 a
Defect ID: DEFECT000319007
Technical Severity: High
Summary: CRC errors reported on Brocade 8000 internal chip-to-chip links.
Symptom: CRC errors on internal links might occur when jumbo frames are transmitted under certain
traffic loads below the full line rate. If extensive CRC errors occur, traffic might stop and
require disabling and enabling to restore affected user ports.
Feature: CEE-Infrastructure
Function: ANVIL DRIVER
Probability: Low
Found in Release: FOS6.3.1
Where Else Fixed: FOS6.3.2 b, FOS6.4.1 a