flow control mode that uses IDLE primitives does not support Brocade frame-based Trunking for
devices such as Time Division Multiplexor (TDM.) In order to overcome this limitation and provide
support for frame-based Trunking with Extended Fabrics, Fabric OS v6.2.0 and later has been
enhanced to support interoperability with these distance extension devices.
Fabric OS v6.3.1 allows Extended Fabrics E_Ports to operate in VC_RDY mode using either ARB or
IDLE primitives as fill words. This allows frame-based Trunking to be supported on Extended Fabrics E-
ports even when IDLE primitives are configured for these ports when operating in native VC_RDY
mode. Prior to this change, frame-based Trunking was supported only when ARB primitives were used
in VC_RDY mode. With Fabric OS v6.2 or later, frame-based Trunking is supported on Extended
Fabrics E_Ports regardless of whether IDLE or ARB primitives are used when operating in native
VC_RDY mode.
Implementation
The portcfglongdistance CLI parameter “VC Translation Link Init” is now overloaded to specify if the
long distance link should use IDLE or ARB primitives. By default, vc_init is enabled. If vc_init is
enabled, the long distance link will use ARB primitives. If vc_init is disabled, the link will use IDLE
primitives.
Note:
Buffer to Buffer Credit Recovery feature is not supported on Extended Fabrics E_Port when it is
configured to use IDLE primitives. The user must disable buffer to buffer credit recovery feature using
the command portcfgcreditrecovery and specifying the disable option; otherwise, the link will
continuously reset.
The Adaptive Networking SID/DID Traffic Prioritization QoS feature is not supported on Extended
Fabrics E_Ports when IDLE primitives are configured on these ports. This is because in this mode only
data Virtual Channels are available while QoS related virtual channels are not available.
When connecting to an extension device that does not support ARB primitives (such as some TDM
products), the following configuration must be used:
portcfgqos -disable <port>
portcfgcreditrecovery disable <port>
portCfgLongDistance <port> <LD|LD> 0 <distance>
The fabric parameter “fabric.ops.mode.longdistance” is now deprecated and should not be used.
Miscellaneous
When ports on a 5470 embedded switch are configured for 8G, Emulex HBAs may not login in
time and cause boot over SAN failures. Setting the port to auto-negotiate allows these HBAs
to log in correctly at 8G.
POST diagnostics for the Brocade 5100 have been modified beginning with FOS v6.3.1b and
v6.4.0 to eliminate an “INIT NOT DONE” error at the end of an ASIC diagnostic port loopback
test. This modification addresses BL-1020 Initialization errors encountered during the POST
portloopbacktest. (Defect 263200)
It is recommended that no more the 50 F_Port Top Talkers be enabled on a 48000 director in
a large fabric (>4000 devices).
It is recommended that for directors with more than 300 E_Ports, the switch be disabled prior
to executing the “switchCfgTrunk” command (used to disable or enable trunking on the
switch).
During non-disruptive firmware upgrades, E_Ports in R-RDY mode may cause some frame
drops on the E-port links.