HP DC SAN Backbone Director Switch Hardware Reference Guide (5697-2158, August 2012)

Figure 40 WWN bezel (logo plate) and WWN card
Installing the WWN bezel (logo plate) and WWN card
CAUTION: Wear a grounded ESD strap when handling the WWN card. Use the grounding
connections above the power connectors on the chassis.
To install the WWN bezel and WWN card:
1. Unpack the new WWN card and save the packaging for the faulty WWN card.
2. Install the WWN card as follows:
To install a WWN card that has handles: Hold the card by the handles and orient with
the LEDs at the bottom. Align the connector on the card with the connector on the chassis
(the connectors are keyed to ensure correct installation) and use the push pad” to press
the card onto the connector until it is seated.
To install a WWN card that does not have handles: Hold the card by the edges and
press the card onto the connector until it is fully seated. Use the Phillips screwdriver and
the two screws to attach the WWN card to the chassis.
3. Install the WWN bezel. Orient the bezel on the chassis (see Figure 40 (page 80)).
4. Insert and tighten the four screws (see Figure 40 (page 80)).
NOTE: If a serial console session is active, several removal detected and insertion
detected messages display on the console because of the replacement.
5. In the CLI session, enter continue to indicate that the replacement has been completed.
Please enter the word `continue' after the new WWN card has been installed: continue
Restoring the information to the replacement FRU now, please wait about 20 seconds
nl
to complete
Verifying the replacement FRU now...
WWN card hot swap is now complete.
FRU replacement completed successfully!
6. Verify that the WWN card is correctly connected by observing the LEDs on the WWN card
to see if they reflect the status of the components.
80 Replacing DC SAN Director FRUs