HP DC SAN Backbone Director Switch Hardware Reference Guide (5697-2158, August 2012)

Factory Part Num: 60-0001501-07
Factory Serial Num: FT02X805BE2
Manufacture: Day: 26 Month: 3 Year: 2007
Update: Day: 14 Month: 3 Year: 2009
Time Alive: 207 days
Time Awake: 3 days
<output truncated>
rsl8-st03-dcx-1:admin>
d. Create a SAN profile by entering and recording the information provided by the following
commands:
nsShow
nsAllShow
switchShow
fabricShow
Copy the command output into a text file named SANbefor.txt. After the DC SAN
Director is restored to the fabric, this information can be used to verify that no unintentional
changes have occurred to the fabric.
rsl8-st03-dcx-1:admin> nsshow
Type Pid COS PortName NodeName TTL
<output truncated>
rsl8-st03-dcx-1:admin> nsallshow
12 Nx_Ports in the Fabric
<output truncated>
rsl8-st03-dcx-1:admin> switchshow
switchName: switch
<output truncated>
rsl8-st03-dcx-1:admin> fabricshow
Switch ID Worldwide Name Enet IP Addr FC IP Addr Name
<output truncated>
rsl8-st03-dcx-1:admin>
e. Enter the supportShow command, and then copy the command output into a text file
named spptshow.txt.
NOTE: The supportShow command has a very long output and time for completion.
It may last 20 minutes or longer depending on the size of the SAN.
This file provides a backup of all the information that might be required by Technical
Support. The information can be used after the DC SAN Director is restored to the fabric,
to verify that no unintentional changes have occurred to the fabric.
rsl8-st03-dcx-1:admin> supportshow
version: 6.0.0
<output truncated>
rsl8-st03-dcx-1:admin>
f. Record the cable connections between the DC SAN Director and the target device and
ports (see Table 19 (page 94)).
86 Replacing DC SAN Director FRUs