HP DC SAN Backbone Director Switch Hardware Reference Guide (5697-2158, August 2012)

d. Verify that the command displays the correct serial numbers.
rsl8-st03-dcx-1:root> fruinfoset chassis 1
ID: (none) >
PN: (none) >
SN: (none) > OEMssn12345
RV: (none) >
Chassis SN: (none) > FT00X8008A4
New FRU Info for: chassis(wwn) 1
ID: none
PN: none
SN: OEMssn12345
RV: none
Chassis SN: FT00X8008A4
rsl8-st03-dcx-1:root>
3. Verify that the chassis serial number has been entered correctly by entering the chassisShow
command at the prompt.
Verifying that the system is operating correctly
To verify that the DC SAN Director is operating correctly:
1. Log in to the DC SAN Director as admin.
rsl8-st03-dcx-1:admin> login
login: admin
password: xxxxxxxx
rsl8-st03-dcx-1:admin>
2. Enter the slotShow -m command and verify that all the installed cards are detected and
that their status is operational (enabled).
rsl8-st03-dcx-1:admin> slotShow -m
Slot Blade Type ID Model Name Status
--------------------------------------------
1 AP BLADE 75 FX8-24 ENABLED
2 AP BLADE 75 FX8-24 ENABLED
3 SW BLADE 51 FC8-48 ENABLED
4 UNKNOWN VACANT
5 CORE BLADE 52 CR8 ENABLED
6 CP BLADE 50 CP8 ENABLED
7 CP BLADE 50 CP8 ENABLED
8 CORE BLADE 52 CR8 ENABLED
9 SW BLADE 51 FC8-48 ENABLED
10 SW BLADE 51 FC8-48 ENABLED
11 SW BLADE 51 FC8-48 ENABLED
12 UNKNOWN VACANT
rsl8-st03-dcx-1:admin>
3. Verify that the DC SAN Director is functioning correctly by entering the switchShow or
switchStatusShow commands.
This switchShow command displays DC SAN Director and port status information.
rsl8-st03-dcx-1:admin> switchshow
switchName: rsl8-st03-dcx-1
switchType: 62.1
switchState: Online
switchMode: Native
switchRole: Subordinate
switchDomain: 11
switchId: fffc0b
90 Replacing DC SAN Director FRUs