HP DC SAN Backbone Director Switch Hardware Reference Guide (5697-2158, August 2012)

Verifying that the configuration of the fabric is correct
HP recommends that you copy the command outputs from this section into a file.
To verify correct configuration of the fabric:
1. Create an after” SAN profile by entering the following commands and copying the output
to a text file named SANafter.txt:
nsShow
nsAllShow
switchShow
lscfg --show (if using the VF feature)
fabricShow
rsl8-st03-dcx-1:admin> nsshow
Type Pid COS PortName NodeName TTL(sec)
N 020f00; 3;10:00:00:01:73:00:29:46;10:00:00:01:73:00:29:46; na
Fabric Port Name: 20:0f:00:60:69:90:03:f0
<output truncated>
rsl8-st03-dcx-1:admin> nsallshow
{
020f00 021fda 021fdc 021fe0 021fe1
5 Nx_Ports in the Fabric}
rsl8-st03-dcx-1:admin> switchshow
switchName: rsl8-st03-dcx-01
<output truncated>
rsl8-st03-dcx-1:admin> lscfg --show
Created switches: 128(ds) 1 2(bs)
Port 0 1 2 3 4 5 6 7 8 9
-------------------------------------------------------------------
FID 1 | 1 | 1 | 1 | 1 | 128 | 128 | 128 | 128 | 128 |
<output truncated>
rsl8-st03-dcx-1:admin> fabricshow
Switch ID Worldwide Name Enet IP Addr FC IP Addr Name
<output truncated>
rsl8-st03-dcx-1:admin>
2. Determine any differences between the information in the SANafter.txt file and the
information in the SANbefor.txt file created earlier. In particular, look for differences in
the following:
Device types
Number of devices
ISL and port states
Number of switches in the fabric
Replacing the DC SAN Director chassis 93