Brocade Network Advisor SAN User Manual v11.1x (53-1002167-01, May 2011)

Brocade Network Advisor SAN User Manual 1069
53-1002167-01
Database tables and fields
E
Switch port
TABLE 237 GIGE_PORT
Field Definition Format Size
ID* int
SWITCH_PORT_ID ID for the GigE Port in SWITCH_PORT. int
PORT_NUMBER GigE Port Number(0 for ge0 and 1 for ge1). int
SLOT_NUMBER Slot number on which the GigE Port is present. int
ENABLED Enabled or disabled.
Default value is 0.
smallint
SPEED Port speed details.
Default value is 0.
bigint
MAX_SPEED Port maximum speed supported. bigint
MAC_ADDRESS MAC Address of that port. varchar 64
PORT_NAME GigE Port Name. varchar 64
OPERATIONAL_STATUS LED status. int
LED_STATE LED status. smallint
SPEED_LED_STATE GigE Port type details. smallint
PORT_TYPE Port type for the GigE Port. varchar 64
PERSISTENTLY_DISABLED Whether the GigE Port is persistently disabled. smallint
INTERFACE_TYPE smallint
CHECKSUM varchar 16
FCIP_CAPABLE 1 = FCIP capable; otherwise, 0.
Default value is 2.
smallint
ISCSI_CAPABLE 1 = ISCSI capable; otherwise, 0.
Default value is 2.
smallint
REMOTE_MAC_ADDRESS MAC address of attached port of the 10G GigE Port. varchar 64
INBAND_MANAGEMENT_ST
ATUS
1 = Inband Management status is enabled;
otherwise, 0.
Default value is 0.
smallint
OCCUPIED Default value is 0. smallint
LAST_UPDATE bigint
TABLE 238 SWITCH_PORT
Field Definition Format Size
ID* int
VIRTUAL_SWITCH_ID DB ID of virtual_switch to which this port belongs. int
WWN WWN of the port. char 23
NAME User friendly name of the port. char 32
SLOT_NUMBER Slot number.
Default value is 0.
int