Brocade Network Advisor SAN User Manual v11.1x (53-1002167-01, May 2011)

766 Brocade Network Advisor SAN User Manual
53-1002167-01
Performance troubleshooting
26
Performance troubleshooting
The following section states a possible issue and the recommended solution for Performance
errors.
Problem Resolution
An error message with the following text
displays:
Real Time statistics collection has failed.
Please see master log for details.
Make sure that the following prerequisites for Performance Monitoring Data collection are
met.
1 To collect performance statistics for any protocol type (FC/FCIP/FCOE/GE), the snmp
access control list must have an empty list or the Management server IP must be
included in the access control list.
For example, data collection occurs in the following cases.
Case 1: Default access control list is empty
FCRRouter:admin> snmpconfig --show accesscontrol
SNMP access list configuration:
Entry 0: No access host configured yet
Entry 1: No access host configured yet
Entry 2: No access host configured yet
Entry 3: No access host configured yet
Entry 4: No access host configured yet
Entry 5: No access host configured yet
Case 2: Management Server IP included in access control list
FCRRouter:admin> snmpconfig --show accesscontrol
SNMP access list configuration:
Entry 0: Access host subnet area 172.26.1.86 (rw)
Entry 1: No access host configured yet
Entry 2: No access host configured yet
Entry 3: No access host configured yet
Entry 4: No access host configured yet
Entry 5: No access host configured yet
Verification and Troubleshooting.
To add the server IP address to the access control list, use the following command
from the switch CLI:
FCRRouter:admin> snmpconfig --set accesscontrol
To set the default access control, use the following command from the switch CLI:
FCRRouter:admin> snmpconfig --default accesscontrol