770 Brocade Network Advisor SAN User Manual
53-1002167-01
Port Fencing troubleshooting
26
Port Fencing troubleshooting
The following section states a possible issue and the recommended solution for Port Fencing
errors.
Professional edition login troubleshooting
The following section states a possible issue and the recommended solution for Professional
edition login errors.
Problem Resolution
In a pure M-EOS fabric, fabric level policy
information (for example, Port Fencing Link
threshold) is stored in database based on the
principle switch WWN. Therefore, if you add a
switch to the fabric and the new switch becomes
the Principle switch, the Management
application cannot obtain the policy information
and the threshold is not applied.
Re-assign the threshold to the fabric. For step-by-step instructions, refer to Assigning
thresholds on page 693.
If you segment a switch from a fabric then
rediscover the switch without accepting
changes, the Port Fencing dialog box displays
the switch twice and the port count is doubled.
Right-click on the fabric that the segmented switch (with red minus icon) is part of and
select Accept Changes.
TABLE 47 Professional edition login troubleshooting
Problem Resolution
Login Failed. Only one client allowed. One
client session is active or has not yet timed out.
If you closed the client using Windows Task Manager (End Task or Process) or using Unix
process ID (kill command), successful relaunch of the application may take up to 2
minutes.