Brocade Network Advisor SAN User Manual v11.1x (53-1002167-01, May 2011)

784 Brocade Network Advisor SAN User Manual
53-1002167-01
SAN real-time performance data
27
6. Click the right arrow to move the selected ports to the Selected table.
7. Cl ic k OK.
The Real Time Performance Graphs dialog box displays.
Filtering real-time performance data
To filter real-time performance data from the Real Time Performance Graphs dialog box, complete
the following steps.
1. Open the Real Time Performance Graphs dialog box.
For step-by-step instructions, refer to “Generating a real-time performance graph” on
page 783. The Real Time Performance Graphs dialog box displays.
2. Click Select to change the object type.
3. Select the object type (FC Ports, ISL Ports, Device Ports, EE Monitors, GE Ports, FCIP Tunnels,
Managed HBA Ports, Managed CNA Ports, E Port Trunks, or 10GE Ports) by which you want to
graph performance from the Show list.
NOTE
Devices with 10GE ports must be running Fabric OS 6.4.1ltd or later to obtain the correct
TE port statistics (TX/RX).
4. Right-click anywhere in the Available table and select Expand All.
5. Select the ports or trunks you want to include in the performance graph in the Available table.
Press Ctrl or Shift and then click to select more than one port.
6. Click the right arrow to move the selected ports to the Selected table.
7. Cl ic k OK.
The Real Time Performance Graphs dialog box displays.
8. Select the measure by which you want to gather performance data from the Measures list.
To select more than one measure, click the Additional Measures expand arrows and select the
check box for each additional measure.
9. (Optional) Enter a value (percentage) in the Reference Line field to set a reference for the
transmit and receive utilization.
Note that this field is only available when you select Tx % Utilization or Rx % Utilization from the
Measures list.
10. Select the granularity at which you want to gather performance data from the Granularity list.
11. Select the Interpolate check box to use interpolation to fill existing gaps, if necessary.
12. (Optional) Click Other Options and select the Use Same Y-axis check box to make the Y-axis
range the same for object.
The Use Same Y-axis check box is only available when you select Rx MB/sec and Tx MB/sec
from the Measures list. You do not have to apply this change, the performance graph
automatically updates.
13. Move the Row Height slider to the left to make the row height smaller or to the right to make it
bigger.