Editing a policy monitor
29
6. Choose one of the following options:
To use the default frequency (one time, runs at current system time plus fifteen minutes),
go to step 7.
To configure the frequency, click the ellipsis button and choose one of the following
options to configure the frequency at which deployment runs for the policy monitor:
To configure deployment to run only once, refer to “Configuring a one-time policy
monitor schedule” on page 839.
To configure hourly deployment, refer to “Configuring an hourly policy monitor
schedule” on page 840.
To configure daily deployment, refer to “Configuring a daily policy monitor schedule”
on page 840.
To configure weekly deployment, refer to “Configuring a weekly policy monitor
schedule” on page 840.
To configure monthly deployment, refer to “Configuring a monthly policy monitor
schedule” on page 841.
7. To s e t p oli c y m onitor s for fabrics, select the Fabric Checks tab and complete the following
steps.
a. Select the Check zoning status check box to determine if zoning is enabled or disabled on
the fabric.
Select the Enabled option to determine if zoning is enabled.
Select the Disabled option to determine if zoning is disabled.
b. Select the Check that all zones belong to at least one zone config check box to determine
if there are orphaned zones in the fabric zone database.
c. Select the Check the number of initiator ports zoned to each storage port check box to
determine the total number of initiator ports zoned to each storage port.
d. Enter the initiator port limit in the Initiator Port Limit field.
The default recommended is 20.
e. To add fabrics, select the fabrics to which you want to apply this policy in the Available
Fabrics table and click the right arrow button.
The selected fabrics display in the Selected Fabrics table.
f. To remove fabrics, select the fabrics to which you do not want to apply this policy in the
Selected Fabrics table and click the left arrow button.
The removed fabrics display in the Available Fabrics table.
8. To set policy monitors for switches, select the SAN Switch Checks tab and complete the
following steps.
a. Select the Check if the product is configured to send events to this server check box to
determine if the Management application server is registered as an SNMP and Syslog
recipient.
b. Select the Check for redundant connections to neighboring switches check box to
determine if there are at least the minimum number of configured ISLs between each
switch pair.