860 Brocade Network Advisor SAN User Manual
53-1002167-01
SNMP traps
30
4. Save the file.
The Management application recompiles all the MIB files. If compilation is successful, the
traps can now be registered in the Event Reception dialog box.
NOTE
If there are compilation errors, you can view the errors in the server log
<install dir>\logs\server\server.log (Windows) or <install dir>/logs/server/server.log (UNIX).
5. If you make changes to the MIB file, open the mibs_to_compile.txt file and save the file.
The Management application recompiles the MIB files and reloads the changes.
Trap customization
The Trap Configuration tab of the Event Reception dialog box enables you to configure the following
settings:
Register and unregister traps of various management information bases (MIBs)
Customize trap description messages based on varbinds and severity and specify alias names.
Registering traps
Traps must be registered in the Event Reception dialog box to make them available. Perform the
following steps to register traps.
1. Select Monitor > SNMP Setup > Event Reception.
2. Click the Trap Configuration tab.
The Trap Configuration tab of the Event Reception dialog box, shown in Figure 379, displays.
The Registered and Not Registered buttons at the top of the Traps tree serves as a filter for the
traps. If there are unregistered traps, they are listed when you select the Not Registered
button.
Traps appear under each MIB folder. The MIB folders correspond to the MIBs identified in the
mibs_to_compile.txt file.