Viewing FCIP connection properties
12
- FICON Tape Read Max Ops defines a maximum number of concurrent emulated tape read
operations. The range is 1-32.
- FICON Tape Write Timer defines a time limit for pipelined write chains. This value is be
specified in milliseconds (ms). If a pipelined write chain takes longer than this value to
complete, the ending status for the next write chain will be withheld from the channel. This
limits processing to what the network and device can support. Too small a value limits
pipelining performance. Too large a value results in too much data being accepted for one
device on a path. The range is 100-1500.
- FICON Tape Max Write Chain defines the maximum amount of data that can be contained
in a single CCW chain. If this value is exceeded, emulation is suspended.
- FICON Oxid Base defines the base value of an entry pool of 256 OXIDs supplied to
emulation generated exchanges. It should fall outside the range used by FICON channels
and devices to avoid conflicts. The range is 0x0000 to 0xF000.
- FICON Debug Flags defines optional debug flags. This is primarily for use by technical
support personnel.
Viewing FCIP connection properties
The FCIP connection properties show properties of the blades or switches on both sides of a
connection. To view FCIP connection properties, right-click the connection between two extension
blades or switches (Figure 141).
FIGURE 141 FCIP connection properties