Data Center Fabric Manager Professional User Manual v10.3.X (53-1001355-01, November 2009)

160 DCFM Professional User Manual
53-1001355-01
Viewing port optics
5
2. Review the port optics information.
Slot/Port #—The slot and port number of the selected fabric.
FC Address—The Fibre Channel address of the port.
TX Power—The power transmitted to the SFP in dBm and uWatts.
NOTE
The uWatts display requires devices with Fabric OS 6.1.0 and later. Devices running Fabric
OS 6.0.0 and earlier only display dBm.
RX Power—The power received from the port in dBm and uWatts.
NOTE
The uWatts display requires devices with Fabric OS 6.1.0 and later. Devices running Fabric
OS 6.0.0 and earlier only display dBm.
Transceiver Temp—The temperature of the SFP transceiver.
Vendor—The vendor of the SFP.
Vendor OUI—The vendor’s organizational unique identifier (OUI).
FC Speed—The FC port speed; for example, 400 Mbps.
Distance—The length of the fiber optic cable.
Vendor PN—The part number of the SFP.
Vendor Rev—The revision number of the SFP.
Serial #—The serial number of the SFP.
Data Code—The data code.
Media Form Factor—The type of media for the transceiver; for example, single mode.
Connector—The type of port connector.
Wave Length—The wave length.
Encoding—Displays how the fiber optic cable is encoded.
Voltage (mVolts)—The voltage across the port in mVolts.
3. Sort the results by clicking on the column header.
4. Rearrange the columns by dragging and dropping the column header.
5. Click Cancel to close the Port Optics (SFP) dialog box.
Refreshing port optics
To refresh port optics, click Refresh.
The Management application retrieves updated port optic information.