Data Center Fabric Manager Professional User Manual v10.3.X (53-1001355-01, November 2009)

278 DCFM Professional User Manual
53-1001355-01
Editing a LAG
11
3. Click Edit.
The Edit LAG dialog box displays.
FIGURE 89 Edit LAG dialog box
4. Modify the following LAG parameters as required:
5. Configure the following LAG parameters:
NOTE
A LAG restriction exists whereby you can add 802.1x-enabled ports to a LAG, but the port will
fail when the LAG is saved to the switch. 802.1x-enabled ports are not supported.
Status - Enabled or Disabled. You must enable the LAG to use the CEE functionality.
Name - The system-generated, read-only LAG name, assigned when the LAG is added.
LAG ID - The LAG identifier, which is not an editable field.
Interface Mode - L2 or none.
A port must be in L2 Mode if you are adding the port as a member of a LAG.
You cannot change the Interface Mode from L2 to none if the LAG is assigned to a
VLAN.
L2 Mode - Select the L2 mode (Access or Trunk).
6. Select at least one available CEE port from the Available Members table and click the right
arrow button to move them to the LAG Members table.
The CEE ports are now part of the link aggregation group.