Return codes
0 OK
CAUTION: The changes made using the P6000 Cluster Extension password management utility
(clxpmu) are only saved on the local node on which it is run. To make the changes global, you
must manually run clxpmu on each node or copy the file clxsmiscfg to each node in the cluster
after you save the changes in clxpmu. HP recommends that you create a backup copy of the
clxsmiscfg file before running clxpmu.
clxpmu main menu
DescriptionMenu choice
View a list of configured management servers in the following format: hostname host
IP:SMI-S port number login:loginSSL:[SSLyes/SSLno]
1) View existing entries
Select a management server to delete from list.2) Delete existing entry
This function requires you to enter the password for the selected HP SMI-S server before
the operation can be performed.
Add the following information to the list of host managers:3) Add new entry
Host name: Host name for a management server.
Host IP: IP address for a management server.
Port: Port to connect to a management server (default is 5988 if no SSL or 5989 if
SSL).
Login name: Login to connect to SMI-S server.
Password: Password connect to SMI-S server.
Use SSL: Specify if you will be connecting using SSL.
Select a host from a list of configured management servers and modify the following
properties:
4) Modify existing entry
Host name
Host IP
Port
Login name
Password
Use SSL
This function requires you to enter the password for the selected HP SMI-S server before
changes can be performed.
Save changes to the configuration file (clxsmiscfg) and exit clxpmu.5) Save changes and quit
Exit clxpmu.6) Quit without saving
changes
Pre-execution and post-execution programs
P6000 Cluster Extension can invoke pre-execution and post-execution programs prior to or after
a P6000 Cluster Extension failover/failback function. These programs can be any executable, and
must be able to provide return codes to P6000 Cluster Extension. If the programs add significant
execution time to the application service startup process, the timeout values for the startup process
must be adjusted in the cluster software.
P6000 Cluster Extension transfers information as CLI arguments to the pre-execution and
post-execution programs. You must not specify CLI arguments. Pre-executables and post-executables
must be specified by full path in the PreExecScript and PostExecScript objects. If no executable is
60 CLI commands and utilities