HP Color LaserJet CP6015 Series - User Guide

Item Sub-item Values Description
BLACK LASER SCANNER
CYAN LASER SCANNER
MAGENTA LASER SCANNER
YELLOW LASER SCANNER
FUSER MOTOR
FUSER PRESSURE RELEASE
MOTOR
BLACK ALIENATION MOTOR
CYAN ALIENATION MOTOR
MAGENTA ALIENATION MOTOR
YELLOW ALIENATION MOTOR
ITB CONTACT/ALIENATION
PAPER TRANSPORT MOTOR
TRAY 1 PICKUP SOLENOID
TRAY 2 PICKUP MOTOR
TRAY 2 PICKUP SOLENOID
TRAY 3 PICKUP MOTOR
TRAY 3 PICKUP SOLENOID
TRAY 4 PICKUP MOTOR
TRAY 4 PICKUP SOLENOID
TRAY 5 PICKUP MOTOR
TRAY 5 PICKUP SOLENOID
DUPLEXER REVERSE MOTOR
DUPLEXER REFEED MOTOR
REPEAT ONCE (default)
CONTINUOUS
Allows the user to specify the
number of times the device
sequences. To terminate the test at
any time the user can press Stop.
PRINT/STOP TEST Range is 0 - 60,000 milliseconds.
The default is 0.
Isolates print quality faults more
accurately by stopping the product
in mid-print cycle, which allows you
to see where the image begins to
degrade. This causes a jam
message that might need to be
manually cleared. A service
representative should perform this
test.
COLOR BAND TEST PRINT TEST PAGE Prints a color band test page that is
used to identify arcing in the high-
voltage power supply.
ENWW Diagnostics menu 45