HP P6000 Command View 9.4 Release Notes (T5494-96472, October 2011)

Fixes
The following fix has been implemented in HP Command View EVAPerf 9.4:
hc command did not display entire WWN for iSCSI/ FCoE hosts—The complete WWN of the host
HBA is now displayed.
Evaperf rc command displays incorrect error message for wrong WWN—Correct error message
is now displayed for wrong WWN input value to rc command.
Workarounds and limitations
Domain names not supported in hostname parameter of fnh command
If the host name you specify in the fnh command is a full domain name (for example,
nt12345.asiapacific.xyzcompany.net <mailto:xyz@asiapacific.xyzcompany.net>),
the friendly names host file is not created.
Use localhost or the host name without the domain when running the fnh command. Examples of
supported entries follow:
evaperf fnh localhost hpadmin@localhost
evaperf fnh nt12345 xyz@asiapacific.xyzcompany.net
Windows Performance Monitor limitations
When using Windows Performance Monitor to view HP Command View EVAPerf performance data
on a management server running Windows 2003 Enterprise Edition, Windows Performance Monitor
may hang when the number of counters exceeds 900 (for example, a virtual disk object that exceeds
100 instances, with 9 counters per instance).
pd and hps command limitation
The incorrect enclosure and bay IDs are displayed in the evaperf pd command when running VCS
4.100 or XCS 6.000.
HSV100 controllers running VCS 4.100 report inconsistent enclosure and bay IDs on both
controllers.
HSV200 controllers running XCS 6.000 report the enclosure and bay ID as "-" on one of the
controllers after a reboot.
evaperf nall command fails to execute
The evaperf nall command fails to execute in continuous mode on a Windows 2008 server in
both local mode and remote mode. Use the evaperf all command instead.
hist command limitation
When used with the object type state_diskgroup, the hist command does not display data for
the EVA4400 and EVA6400/8400.
HP SMI-S EVA 9.4
HP SMI-S EVA 9.4 is shipped with the HP P6000 Command View software suite. HP SMI-S EVA enables
Common Information Model (CIM)-capable management software to manage EVA storage systems.
HP SMI-S EVA is based on the Managed Object Format (MOF) 2.15 and is SMI-S 1.4 compliant.
NOTE: If a version of HP SMI-S EVA earlier than 8.0.x is installed, you must remove it before installing
HP SMI-S EVA 9.4.
12 HP SMI-S EVA 9.4